*As of June 2003 for image sensor cameras
 |

VISUAL STATION is equipped with "Image processing procedure automatic generating expert" developed based on the know-how of image processing experts, and the analysis and collection of academic data. By simply entering the parameters according to the instruction on the screen and draw round the inspecting area with stylus pen, processing procedure will be automatically generated and executed. Image will be quickly extracted. Reducing the personal difference and shortening the time, this system improved efficiency and uniformity of the work. |






Place the separately-sold reference plate for distortion correction under the camera, and enter the correct scale distance, then execute.




Turn the focus adjuster to the point at which the bar display shows the maximum value.

*As of June 2003 for image sensor cameras



New algorism reinforces the functions of conventional gray search (correlation for normalization). This system provides a stable search even if the workpiece you wish to search is partially hidden or chipped. (Patent pending)


VISUAL STATION can work with double-speed cameras with progressive system CCD. Partial image capture function speed up the image-capturing. And further reduction of time can be possible by selecting from 4 modes to suite your inspection/measurement purpose. |









| * |
Partial image is captured when 240 lines out of 480 lines are read. |
| * |
Standard cameras: IV-S30C1/IV-S30C2, high speed camera: IV-S30C3/IV-S30C4 |
| * |
Full mode: odd /even lines are read, half mode: only odd lines are read. |
| (Notice) |
Image-capture time will differ depending on the position of partial image (max. 0.4ms in the case above) |


During the operation, the light volume on the workpiece used to be inconsistent due to the changes of surrounding environment. Inconsistency of the light volume could change the image's light level, and hinder the stable inspection/measurement results. VISUAL STATION uses light level automatic adjustment system with illuminance monitoring function that provides the stable screen image with the consistent light level.


VISUAL STATION is equipped with lighting control function. When lighting power source for lighting control is used, general-purpose serial interface can control ON/OFF of the lighting, diagnose the light volume, and remotely control the lighting volume. This function allows you to prevent from improper detection caused by the lowered light volume. |


*Contact our sales representative for the recommended lighting power source.

 |
| With window for trigger set up, no need for any external sensor even for moving measurement. You can select your trigger detection method from binary processing, average light level and gray search. Gray search can be used for the workpieces for which setting of the light range is tricky. |
 |


VISUAL STATION is equipped with Ethernet interface that allows fast communication to upward personal computer. You can see measured data and NG images at a personal computer which is located away from the inspection site. Parameter setting support software (IV-S51SPM) can be installed at a personal computer.




| *As of June, 2003 for image sensor cameras |
|